flopy.mf6.modflow.mfgwfrcha module

class ModflowGwfrcha(model, loading_package=False, readasarrays=True, fixed_cell=None, auxiliary=None, auxmultname=None, print_input=None, print_flows=None, save_flows=None, timearrayseries=None, observations=None, irch=None, recharge=0.001, aux=None, filename=None, pname=None, parent_file=None)[source]

Bases: flopy.mf6.mfpackage.MFPackage

ModflowGwfrcha defines a rcha package within a gwf6 model.

Parameters:
  • model (MFModel) – Model that this package is a part of. Package is automatically added to model when it is initialized.
  • loading_package (bool) – Do not set this parameter. It is intended for debugging and internal processing purposes only.
  • readasarrays (boolean) –
    • readasarrays (boolean) indicates that array-based input will be used for the Recharge Package. This keyword must be specified to use array-based input.
  • fixed_cell (boolean) –
    • fixed_cell (boolean) indicates that recharge will not be reassigned to a cell underlying the cell specified in the list if the specified cell is inactive.
  • auxiliary ([string]) –
    • auxiliary (string) defines an array of one or more auxiliary variable names. There is no limit on the number of auxiliary variables that can be provided on this line; however, lists of information provided in subsequent blocks must have a column of data for each auxiliary variable name defined here. The number of auxiliary variables detected on this line determines the value for naux. Comments cannot be provided anywhere on this line as they will be interpreted as auxiliary variable names. Auxiliary variables may not be used by the package, but they will be available for use by other parts of the program. The program will terminate with an error if auxiliary variables are specified on more than one line in the options block.
  • auxmultname (string) –
    • auxmultname (string) name of auxiliary variable to be used as multiplier of recharge.
  • print_input (boolean) –
    • print_input (boolean) keyword to indicate that the list of recharge information will be written to the listing file immediately after it is read.
  • print_flows (boolean) –
    • print_flows (boolean) keyword to indicate that the list of recharge flow rates will be printed to the listing file for every stress period time step in which “BUDGET PRINT” is specified in Output Control. If there is no Output Control option and “PRINT_FLOWS” is specified, then flow rates are printed for the last time step of each stress period.
  • save_flows (boolean) –
    • save_flows (boolean) keyword to indicate that recharge flow terms will be written to the file specified with “BUDGET FILEOUT” in Output Control.
  • timearrayseries ({varname:data} or tas_array data) –
    • Contains data for the tas package. Data can be stored in a dictionary containing data for the tas package with variable names as keys and package data as values. Data just for the timearrayseries variable is also acceptable. See tas package documentation for more information.
  • observations ({varname:data} or continuous data) –
    • Contains data for the obs package. Data can be stored in a dictionary containing data for the obs package with variable names as keys and package data as values. Data just for the observations variable is also acceptable. See obs package documentation for more information.
  • irch ([integer]) –
    • irch (integer) IRCH is the layer number that defines the layer in each vertical column where recharge is applied. If IRCH is omitted, recharge by default is applied to cells in layer 1. IRCH can only be used if READASARRAYS is specified in the OPTIONS block. If IRCH is specified, it must be specified as the first variable in the PERIOD block or MODFLOW will terminate with an error. This argument is an index variable, which means that it should be treated as zero-based when working with FloPy and Python. Flopy will automatically subtract one when loading index variables and add one when writing index variables.
  • recharge ([double]) –
    • recharge (double) is the recharge flux rate (\(LT^{-1}\)). This rate is multiplied inside the program by the surface area of the cell to calculate the volumetric recharge rate. The recharge array may be defined by a time-array series (see the “Using Time-Array Series in a Package” section).
  • aux ([double]) –
    • aux (double) is an array of values for auxiliary variable aux(iaux), where iaux is a value from 1 to naux, and aux(iaux) must be listed as part of the auxiliary variables. A separate array can be specified for each auxiliary variable. If an array is not specified for an auxiliary variable, then a value of zero is assigned. If the value specified here for the auxiliary variable is the same as auxmultname, then the recharge array will be multiplied by this array.
  • filename (String) – File name for this package.
  • pname (String) – Package name for this package.
  • parent_file (MFPackage) – Parent package file that references this package. Only needed for utility packages (mfutl*). For example, mfutllaktab package must have a mfgwflak package parent_file.
aux = <flopy.mf6.data.mfdatautil.ArrayTemplateGenerator object>
auxiliary = <flopy.mf6.data.mfdatautil.ListTemplateGenerator object>
dfn = [['block options', 'name readasarrays', 'type keyword', 'shape', 'reader urword', 'optional false', 'default_value True'], ['block options', 'name fixed_cell', 'type keyword', 'shape', 'reader urword', 'optional true'], ['block options', 'name auxiliary', 'type string', 'shape (naux)', 'reader urword', 'optional true'], ['block options', 'name auxmultname', 'type string', 'shape', 'reader urword', 'optional true'], ['block options', 'name print_input', 'type keyword', 'reader urword', 'optional true'], ['block options', 'name print_flows', 'type keyword', 'reader urword', 'optional true'], ['block options', 'name save_flows', 'type keyword', 'reader urword', 'optional true'], ['block options', 'name tas_filerecord', 'type record tas6 filein tas6_filename', 'shape', 'reader urword', 'tagged true', 'optional true', 'construct_package tas', 'construct_data tas_array', 'parameter_name timearrayseries'], ['block options', 'name tas6', 'type keyword', 'shape', 'in_record true', 'reader urword', 'tagged true', 'optional false'], ['block options', 'name filein', 'type keyword', 'shape', 'in_record true', 'reader urword', 'tagged true', 'optional false'], ['block options', 'name tas6_filename', 'type string', 'preserve_case true', 'in_record true', 'reader urword', 'optional false', 'tagged false'], ['block options', 'name obs_filerecord', 'type record obs6 filein obs6_filename', 'shape', 'reader urword', 'tagged true', 'optional true', 'construct_package obs', 'construct_data continuous', 'parameter_name observations'], ['block options', 'name obs6', 'type keyword', 'shape', 'in_record true', 'reader urword', 'tagged true', 'optional false'], ['block options', 'name obs6_filename', 'type string', 'preserve_case true', 'in_record true', 'tagged false', 'reader urword', 'optional false'], ['block period', 'name iper', 'type integer', 'block_variable True', 'in_record true', 'tagged false', 'shape', 'valid', 'reader urword', 'optional false'], ['block period', 'name irch', 'type integer', 'shape (ncol*nrow; ncpl)', 'reader readarray', 'numeric_index true', 'optional true'], ['block period', 'name recharge', 'type double precision', 'shape (ncol*nrow; ncpl)', 'reader readarray', 'default_value 1.e-3'], ['block period', 'name aux', 'type double precision', 'shape (ncol*nrow; ncpl)', 'reader readarray', 'optional true']]
dfn_file_name = 'gwf-rcha.dfn'
irch = <flopy.mf6.data.mfdatautil.ArrayTemplateGenerator object>
obs_filerecord = <flopy.mf6.data.mfdatautil.ListTemplateGenerator object>
package_abbr = 'gwfrcha'
recharge = <flopy.mf6.data.mfdatautil.ArrayTemplateGenerator object>
tas_filerecord = <flopy.mf6.data.mfdatautil.ListTemplateGenerator object>